We are Manufacturer, Supplier, Exporter of Air Water Heat Pump Test Rigs & our setup is situated in Sangli, Maharashtra, India.
RANGE OF EXPERIMENTS
To observe the working principal of heat pump cycle.
To determine Actual cooling C.O.P, Carnot C.O.P., Theoretical C.O.P., Actual heating C.O.P., Relative C.O.P., Ton of Refrigeration Etc.
To determine the efficiency of the heat pump system.
Observe the working of refrigeration cycle also.
EXPERIMENTAL SETUP :
Compressor : ½ Tone, Hermetically sealed compressor, Make Emmelsion – Coplend/equivalent.
Condenser : Coiled Tube Heat Exchanger acts as a condenser. Copper coil is merged in water tank to cool down the gas temp. Continuous water flow circulation is required to extract the heat of gases.
Expansion device : Thermostatic expansion valve.
Evaporator coil : Air Cooled evaporator made out of copper pipe & Aluminum fins of matching capacity with fan.
Rotameter : For measuring liquid flow of Refrigerant (Eureka Make ).
Energy Meter : For power measurement of compressor.
Pressure Gauge : 2 Nos. for H.P., L.P. measurement
HP/LP cutout : 1 No. to suit compressor, Ranko/Equiv.
Service valve needle type : 1 No.
Thermostat : 1 No.
Suitable filter/drier Make Indfoss.
CONTROL PANEL :
12 Channel Digital Temperature Indicator
Dimmerstat : 230 V. AC single phase for heating control